Skip to main content

Stimulated myoblast differentiation on graphene oxide-impregnated PLGA-collagen hybrid fibre matrices

Abstract

Background

Electrospinning is a simple and effective method for fabricating micro- and nanofiber matrices. Electrospun fibre matrices have numerous advantages for use as tissue engineering scaffolds, such as high surface area-to-volume ratio, mass production capability and structural similarity to the natural extracellular matrix (ECM). Therefore, electrospun matrices, which are composed of biocompatible polymers and various biomaterials, have been developed as biomimetic scaffolds for the tissue engineering applications. In particular, graphene oxide (GO) has recently been considered as a novel biomaterial for skeletal muscle regeneration because it can promote the growth and differentiation of myoblasts. Therefore, the aim of the present study was to fabricate the hybrid fibre matrices that stimulate myoblasts differentiation for skeletal muscle regeneration.

Results

Hybrid fibre matrices composed of poly(lactic-co-glycolic acid, PLGA) and collagen (Col) impregnated with GO (GO-PLGA-Col) were successfully fabricated using an electrospinning process. Our results indicated that the GO-PLGA-Col hybrid matrices were comprised of randomly-oriented continuous fibres with a three-dimensional non-woven porous structure. Compositional analysis showed that GO was dispersed uniformly throughout the GO-PLGA-Col matrices. In addition, the hydrophilicity of the fabricated matrices was significantly increased by blending with a small amount of Col and GO. The attachment and proliferation of the C2C12 skeletal myoblasts were significantly enhanced on the GO-PLGA-Col hybrid matrices. Furthermore, the GO-PLGA-Col matrices stimulated the myogenic differentiation of C2C12 skeletal myoblasts, which was enhanced further under the culture conditions of the differentiation media.

Conclusions

Taking our findings into consideration, it is suggested that the GO-PLGA-Col hybrid fibre matrices can be exploited as potential biomimetic scaffolds for skeletal tissue engineering and regeneration because these GO-impregnated hybrid matrices have potent effects on the induction of spontaneous myogenesis and exhibit superior bioactivity and biocompatibility.

Background

Recently, many studies have focused on the fabrication of artificial scaffolds as potential biomimetic substrates, which can control the cellular behaviours and provide appropriate microenvironments. Ideal scaffolds should have a suitable structure for the growth of cells because they interact directly with the cells. In addition, these scaffolds should have biofunctionality because the cell fate is controlled by various mechanical and biochemical cues from the surrounding environment. Therefore, over the past few years considerable efforts have been made to meet these requisites using a variety of methods and materials. Several techniques have been used to fabricate artificial scaffolds that mimic the natural extracellular matrix (ECM) such as electrospinning, self-assembly, phase separation, and drop casting [1,2]. Among these techniques, electrospinning has attracted numerous interests as a simple and effective method [3]. Many studies have reported that artificial scaffolds composed of biocompatible polymers and various biomaterials can be manufactured by electrospinning [3-8]. In particular, electrospun matrices, composed of various polymers, including polyesterurethane, poly(ε-caprolactone) and poly(hydroxybutyrate), coated with proteins or not, have been designed as potential artificial scaffolds for skeletal muscle regeneration [9-12].

Over the last decade, poly(lactic-co-glycolic acid, PLGA), collagen (Col) and/or their combination have been used extensively as artificial scaffolds [13-16]. Col is a major component of the ECM and has been widely used as a representative biomaterial for the tissue engineering applications because of its many advantages, including excellent biocompatibility, cell affinity and bioresorbability. On the other hand, the poor mechanical and rapidly degrading properties of Col remain obstacles to its use as a scaffold for tissue engineering. PLGA is a biocompatible polymer that is extensively used for a range of biomedical applications, such as surgical suturing, drug delivery carriers, and tissue engineering scaffolds because of its outstanding features, such as biocompatibility, biodegradability, good solubility in organic solvents, and suitable mechanical properties for scaffolds [17-19].

Graphene, a single two-dimensional layer of carbon, and its derivatives have attracted considerable attention for biomedical applications, such as scaffold substrates, drug or gene delivery carriers, and bio-sensors [20-23]. Graphene oxide (GO) is the oxidised form of graphene and has many oxygen-containing functional moieties, such as hydroxyl, carboxyl and epoxy groups. Recently, it was reported that GO has good biocompatibility and can enhance both the mechanical properties of the substrates and the cellular behaviours [24-27]. Therefore, GO might have potential use as a bio-building block for scaffold substrates. In the present study, GO-impregnated biomimetic matrices composed of PLGA and Col (GO-PLGA-Col), which are analogous to the natural ECM, were fabricated via an electrospinning process. The use of PLGA-Col in combination with GO is novel and challenging. The hypothesis tested was whether these GO-PLGA-Col hybrid fibre matrices would be beneficial to myoblast differentiation. For this purpose, the physicochemical and mechanical properties of the matrices were characterised by field emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), Fourier transform-infrared (FT-IR) spectroscopy, contact angle measurements, X-ray diffraction (XRD), and tensile tests. Furthermore, the cellular behaviours of C2C12 skeletal myoblasts cultured on GO-PLGA-Col hybrid matrices were examined to explore their biocompatibility and bioactivity.

Results and discussion

Physicochemical and mechanical characteristics of GO-PLGA-Col fibre matrices

GO-PLGA-Col hybrid fibre matrices were prepared by electrospinning the admixture of PLGA and Col blended with GO. The matrices contained a large number of black spots scattered throughout the matrix due to impregnated GO (Figure 1). The physicochemical properties of the GO-PLGA-Col hybrid matrices were characterised by FESEM, AFM and FT-IR spectroscopy. As shown in Figure 2A, FESEM images showed that all matrices had a three-dimensional network structure with interconnected pores similar to that of the natural ECM. The diameter of the GO-PLGA-Col fibres showed a wide range between 100 and 950 nm with the average diameter of 440 nm due to the random alternation of Col and PLGA as well as GO impregnation. The average diameter of the hybrid fibres substantially decreased when GO, Col or both were blended with PLGA. A series of evidence supports this result, showing that the average diameter of the PLGA fibres blended with GO or Col is much smaller than that of pure PLGA fibres [28,29]. This phenomenon can be explained partly by the fact that the viscosity of the electrospinning solution was decreased due to the blending of GO and/or Col [30]. The surface topography of each fibre matrix correlated well with its own FESEM image (Figure 2B). The average surface roughness (R a) of PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col fibre matrices was 1.30, 0.58, 0.75, and 0.52 μm, respectively. The surface roughness of the matrices was closely related to the fibre diameter (Figure 2C). Some previous studies have revealed that the surface roughness of the fibrous matrices decreases with decreasing diameter of the constituent fibre [31,32]. Furthermore, there is a general tendency that the surface-area-to-volume ratio of matrices increases with decreasing fibre diameter [33]. Therefore, it is suggested that GO-PLGA-Col matrices would interact easily with the cells due to their increased surface-area-to-volume ratio.

Figure 1
figure 1

Digital photographs of the PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col fibre matrices. All photographs shown in this figure are representative of six samples with similar results.

Figure 2
figure 2

Surface morphological and topographical images of PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col fibre matrices. (A) FESEM images and (B) AFM images of PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col fibre matrices. All photographs shown in this figure are representative of six independent experiments with similar results. (C) Correlation between fibre diameter of matrices and their surface roughness (R a). The different letters in (C) denote the significant differences between each experimental group, p < 0.05. If two groups have the same single letter (a, b), there is no significant difference between them.

Figure 3A shows the FT-IR spectra of PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col fibres. In the GO-PLGA-Col fibres, a noticeable band was observed at 1752 cm−1, which was assigned to the C = O stretching vibration. This band was derived from PLGA and GO [34]. The characteristic band for Col was observed at 1546 cm−1, which can be attributed to the amide II vibration from the N-H bending and C-N stretching vibrations [35]. On the other hand, another band at 1632 cm−1 was observed, which was assigned to C = C bonds related to the unoxidised sp2 carbon of GO [36,37]. This result implied that GO and Col were well distributed in the GO-PLGA-Col fibre matrices. The XRD patterns of GO and electrospun matrices are presented in Figure 3B. XRD pattern of GO showed a strong diffraction peak at 11.09°, corresponding to the interlayer spacing of 0.797 nm calculated by using the Bragg equation [38]. In contrast, PLGA and PLGA-Col matrices did not show any diffraction peak due to their amorphous structure. On the other hand, the XRD patterns of GO-PLGA and GO-PLGA-Col matrices exhibited a sharp diffraction peak at 11.46°, corresponding to the interlayer spacing of 0.772 nm. This result indicated that the GO maintained the structure of a single two-dimensional layer of carbon with oxygen-containing functional moieties within the GO-PLGA or GO-PLGA-Col matrices. Figure 3C shows the water contact angles and surface energies of the PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col matrices. The hydrophilicity of the matrices plays an important role in interacting with cells. The water contact angle was 135.0 ± 0.7° for the PLGA matrices, 126.3 ± 0.7° for the GO-PLGA matrices, 95.2 ± 0.4° for the PLGA-Col matrices, and 85.0 ± 0.3° for the GO-PLGA-Col matrices. The water contact angles of the GO-PLGA matrices were slightly decreased by blending with GO because of not only the hydroxyl groups but also the negatively charged groups, such as carboxylic acid groups on the GO surface [25]. On the other hand, the water contact angles of the matrices were significantly (p < 0.05) decreased by blending with Col because of its hydrophilicity. Among the matrices, the lowest contact angle was obtained for the GO-PLGA-Col matrices. In addition, the surface energy of GO-PLGA-Col matrices was measured to be 32.35 mN/m, which was much higher than that of the PLGA matrices (4.96 mN/m). These results suggest that the GO-PLGA-Col matrices have a more hydrophilic surface compared to that of the other matrices. The improvement in the hydrophilicity of the scaffold surface enhances the cellular behaviours, including the initial attachment, proliferation and differentiation [39,40]. Therefore, GO-PLGA-Col matrices can provide a suitable microenvironment for the attachment and proliferation of cells because they have a more hydrophilic surface than the other matrices.

Figure 3
figure 3

Physicochemical characterization of the PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col matrices. (A) FT-IR spectra were recorded in absorption mode in the wavelength range of 1000–2200 cm−1 with a resolution of 4.0 cm−1 and 16-times scanning. (B) XRD patterns of GO, PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col matrices were collected with Cu-Kα radiation (λ = 0.154 nm) at 40 kV and 30 mA. (C) Contact angles of the matrices were measured by the sessile drop method.

Figure 4 shows the stress–strain curves of the matrices under a tensile load. The tensile strength and elastic modulus of the matrices can be obtained from the stress–strain curves. The tensile strengths of the PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col matrices were approximately 3.8, 27.4, 2.9, and 16.8 MPa, respectively. The elastic moduli of the PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col matrices were approximately 140, 690, 50, and 460 MPa, respectively. The elastic moduli were taken as the maximum linear slope of the stress–strain curve in the elastic deformation region [16,41]. When Col was added to the polymer substrates, the mechanical properties of the matrices, such as the tensile strength and elastic modulus, decreased [28,42]. Therefore, the tensile strength and elastic modulus of the matrices were decreased by blending with Col. In contrast, the tensile strength and elastic modulus of the GO-impregnated matrices were remarkably higher than those of the PLGA and PLGA-Col matrices. Previous studies reported that the mechanical properties of substrates were improved by the addition of GO because of the interfacial interaction between the oxygen-containing functional moieties of GO and the hydroxyl or amine groups of the substrates [25,26,43,44]. Therefore, this result suggests that the poor mechanical properties of Col-contained matrices can be reinforced by the impregnation of GO, and the GO-PLGA-Col matrices can serve as mechanically stable scaffolds for cell growth.

Figure 4
figure 4

Stress–strain curves of the matrices. Stress–strain curves of the (A) PLGA, (B) GO-PLGA, (C) PLGA-Col, and (D) GO-PLGA-Col matrices were obtained under a cross-head speed of 10 mm/min. Prior to testing, 4 types of matrices were cut into a rectangular shape, 40 mm in length and 10 mm in width.

Attachment and proliferation of C2C12 skeletal myoblasts on GO-PLGA-Col fibre matrices

C2C12 skeletal myoblasts were cultured on the fibre matrices to evaluate the cellular behaviours including the initial attachment and proliferation on GO-PLGA-Col fibre matrices. C2C12 skeletal myoblasts were seeded on all matrices and the cell viability was measured at 6 hours after seeding. The initial attachment of the C2C12 skeletal myoblasts cultured on the PLGA-Col and GO-PLGA-Col matrices was significantly (p < 0.05) higher than that on the tissue culture plastic (TCP) control, PLGA matrices and GO-PLGA matrices, as shown in Figure 5A and Table 1. This suggests that the initial attachment of cells is influenced greatly by the hydrophilic/hydrophobic properties of the substrate surface. In addition, proliferation of cells on the matrices on 1, 3, 5, and 7 days after incubation was evaluated (Figure 5B and Table 1). The proliferation of cells was consistently increased during the culture period in all groups. On the other hand, the proliferation of cells on the GO-PLGA-Col matrices was significantly (p < 0.05) better than that on the other groups. This might be due to the improved hydrophilicity of the matrices and the ability of GO and Col to support proliferation of cells. Previous studies demonstrated that GO enhances the cellular behaviours, including attachment, proliferation, and even differentiation [24-26,45]. Moreover, it has been well known that Col supports cell attachment and proliferation because of its outstanding biocompatibility and cell affinity [28,29,42]. Many studies have reported that an improvement in attachment or proliferation of myoblasts promotes their myogenic differentiation due to the community effect where cells can undergo myogenic differentiation when they reach confluence for contact of the neighbouring cells [46-52]. Therefore, Col enables not only to enhance attachment and proliferation but also to help myogenic differentiation. It is suggested that the GO-PLGA-Col matrices can effectively promote the initial attachment and proliferation of cells by GO and Col.

Figure 5
figure 5

Initial attachment and proliferation of C2C12 skeletal myoblasts. (A) Initial attachment of C2C12 skeletal myoblasts on tissue culture plastic (TCP), PLGA matrices, GO-PLGA matrices, PLGA-Col matrices, and GO-PLGA-Col matrices were measured using a CCK-8 assay at 6 hours after seeding. (B) Proliferation of C2C12 skeletal myoblasts were measured using CCK-8 assay on 1, 3, 5, and 7 days after incubation. The different letters in (A) denote the significant differences between the control and experimental groups, p < 0.05. The different letters in (B) denote the significant differences between the control and experimental groups at the same time point, p < 0.05. If two groups have the same single letter (a, b, c, etc.), there is no significant difference between them. If a group is marked with a dual letter (eg, de), it has a significant difference from the control and other groups marked with ‘a’, ‘b’, or ‘c’, but does not from another group marked with ‘d’.

Table 1 Initial attachment and proliferation of C2C12 skeletal myoblasts on tissue culture plastic (TCP) and electrospun matrices

Myogenic differentiation of C2C12 skeletal myoblasts on GO-PLGA-Col fibre matrices

The myogenic differentiation of C2C12 skeletal myoblasts on the GO-PLGA-Col matrices was examined by immunofluorescence staining for the myosin heavy chain (MHC), which is a myogenic differentiation marker. C2C12 skeletal myoblasts were seeded on the fibre matrices and incubated in growth media (GM) or differentiation media [DM, Dulbecco’s modified Eagle’s medium (DMEM) containing 2% horse serum and 1% antibiotic-antimycotic solution] for 5 days. After incubation under each condition, expression of MHC and the formation of multinucleate myotubes were analysed by immunofluorescence staining. When C2C12 skeletal myoblasts are fully proliferated, they differentiated with multinucleate myotubes in DM. As shown in Figure 6A, the C2C12 skeletal myoblasts on PLGA matrices attached imperfectly and presented an abnormal morphology. On the PLGA-Col, GO-PLGA-Col matrices, however, C2C12 skeletal myoblasts were well grown and extensively spread out on the matrices. On the other hand, the green fluorescence of MHC was not detected from the C2C12 skeletal myoblasts on the PLGA and PLGA-Col matrices. In contrast, the cells on the GO-PLGA and GO-PLGA-Col matrices exhibited the green fluorescence of MHC. These results indicated that MHC-positive C2C12 skeletal myoblasts on GO-PLGA and GO-PLGA-Col matrices were fused together to form multinucleate myotubes. Meanwhile, as shown in Figure 6B, the C2C12 skeletal myoblasts on all the matrices, except for the PLGA matrices, were differentiated in DM as a positive control. Figure 6C-E and Table 2 show the cell area (μm2/105 μm2), MHC-positive area (μm2/105 μm2) and fusion index (%) to quantify the myogenic differentiation of C2C12 skeletal myoblasts. The fusion index was calculated as a percentage of the nuclei number in multinucleate myotubes with more than two nuclei to the total number of nuclei [53]. As shown in Figure 6C, the cell area of the C2C12 skeletal myoblasts cultured on PLGA-Col and GO-PLGA-Col matrices was significantly (p < 0.05) increased compared to that on the PLGA and GO-PLGA matrices in GM. This result is in accordance with the cell attachment and proliferation profiles. On the other hand, in DM, the cell area of the C2C12 skeletal myoblasts cultured on GO-PLGA matrices was significantly (p < 0.05) increased because the differentiation of cells was effectively facilitated by GO under the differentiation conditions. In addition, the C2C12 skeletal myoblasts cultured on GO-PLGA-Col matrices showed the highest MHC-positive area and fusion index, regardless of the culture condition (Figure 6D and E). This phenomenon can be attributed to the fact that the GO blended within the matrices promotes myogenic differentiation. Many previous studies support this result by showing that graphene and GO can enhance the differentiation of myoblasts, as well as various types of stem cells, such as mesenchymal, neural, embryonic, and induced pluripotent stem cells [45,53-57]. In particular, it has been reported that the GO can stimulate and accelerate the myogenic differentiation of C2C12 myoblasts because the oxygen-containing functional moieties, including hydroxyl, carboxyl and epoxy groups of the GO may increase the adsorption of serum proteins in culture media [53]. Consequently, the GO-PLGA-Col matrices greatly accelerated spontaneous myoblast fusion as well as the myotube maturation of myoblasts cultured in GM because GO can not only to promote differentiation, but also improve the initial attachment and proliferation on the matrices. Some evidence has indicated that an improvement in attachment and proliferation facilitates the differentiation of C2C12 skeletal myoblasts [52,58]. These results indicated that the GO-PLGA-Col matrices are biofunctional scaffolds with the ability to stimulate the differentiation of skeletal myoblasts and enhance the initial attachment and proliferation of skeletal myoblasts. Therefore, it is suggested that GO-PLGA-Col hybrid matrices can be employed as effective biomimetic scaffolds with excellent biocompatibility and biofunctionality.

Figure 6
figure 6

Myogenic differentiation analysis with immunofluorescence staining. Two-photon excitation fluorescence images of C2C12 skeletal myoblasts in (A) growth media (GM) and (B) differentiation media (DM). The cells were cultured in GM for 2 days and then cultured in GM or DM for additional 5 days. The cell nuclei were counterstained with DAPI (blue), the F-actins were stained with TRITC-labelled phalloidin (red) and the myosin heavy chains (MHCs) were stained with FITC-labelled anti-MHC antibody (green). The scale bars are 50 μm. Quantification of (C) the cell area, (D) MHC-positive area, and (E) fusion index. The fusion index was calculated as a percentage of the nuclei number in multinucleate myotubes with more than two nuclei to the total number of nuclei. Quantitative analysis was performed using ImageJ Software. The different letters in (C) and (D) denote the significant differences between each experimental group, p < 0.05. The different letters in (E) denote the significant differences between each experimental group, p < 0.05. If two groups have the same single letter (a, b, c, etc.), there is no significant difference between them. If a group is marked with a dual letter (eg, bc), it has a significant difference from the control and other groups marked with ‘a’, but does not from another group marked with ‘b’.

Table 2 Quantification of the cell area, MHC-positive area and fusion index

Conclusions

This study was designed to develop biomimetic scaffolds composed of GO-PLGA-Col fibres by electrospinning and to investigate their physicochemical and mechanical properties, biocompatibility, and biofunctionality. We successfully fabricated the GO-PLGA-Col hybrid fibre matrices with a three-dimensional porous structure similar to that of the natural ECM. Our results showed that GO was well dispersed and blended with Col in the hybrid matrices. It was also revealed that the hydrophilicity of the PLGA matrices was significantly increased by blending GO and Col. An improvement in surface hydrophilicity can provide a favourable microenvironment for cell attachment and proliferation. In addition, the GO-PLGA-Col matrices can effectively enhance the initial attachment and proliferation of C2C12 skeletal myoblasts. Furthermore, these hybrid matrices can induce the spontaneous myogenic differentiation of myoblasts owing to the synergistic effect of GO and Col. These results suggest that the GO-PLGA-Col matrices have excellent biocompatibility, as well as suitable physicochemical and mechanical properties for biomimetic scaffolds. In conclusion, GO-PLGA-Col matrices have potential use as biofunctional scaffolds for skeletal tissue engineering and regeneration.

Methods

Fabrication of GO-PLGA-Col fibre matrices

GO-PLGA-Col hybrid fibre matrices were fabricated by electrospinning. Briefly, the PLGA resins [PLA:PGA = 75:25 (mol/mol), molecular weight (MW) = 70–110 kDa, Evonik Industries, Essen, Germany] and Col (Darim Tissen, Seoul, Korea) were dissolved in 1, 1, 1, 3, 3, 3-hexafluoroisopropanol (HFIP, Sigma-Aldrich Co., St Louis, MO). The concentrations of PLGA and Col were 200 and 30 mg/ml, respectively. GO was prepared from flake graphite using a modified Hummers’ method [59]. The GO solution in water was prepared by sonicating for 2 hours to distribute the GO evenly throughout the solution and was blended with the PLGA-Col solution. The concentration of GO was 10 mg/ml. The mixture solution of PLGA, Col and GO was then loaded into a syringe (HSW, Tuttlingen, Germany) with a spinneret needle (21-gauge). A voltage of 14 kV was applied using a DC high voltage power supply (NanoNC, Seoul, Korea). A working distance between the needle tip and the collector was 14 cm and the flow rate was 0.2 ml/h. The fabricated GO-PLGA-Col fibres were collected on a steel rotating wheel covered with aluminium foil. After the spinning process, the GO-PLGA-Col fibre matrices were dried overnight under vacuum at room temperature (RT) to remove the residual solvent. Subsequently, the fabricated fibre matrices were cut into 9 mm diameter discs and sterilised by ultraviolet light prior to use.

Physicochemical and mechanical characterisations of GO-PLGA-Col fibre matrices

The matrices were coated with an ultrathin layer of gold/platinum prior to analysis. The surface morphology of the matrices was observed by FESEM (Hitachi S-4700, Tokyo, Japan) at an accelerating voltage of 5 kV.

The topography of the matrices was characterised by AFM (NX10, Park Systems Co., Suwon, Korea) in air at RT. Imaging was performed in non-contact mode with a Multi 75 silicon scanning probe at a resonant frequency of ~300 kHz. Image analysis was performed using XEI Software (Park Systems Co.).

Compositional analysis of the GO-PLGA-Col fibre matrices was performed by FT-IR spectroscopy. The FT-IR spectra were collected by a FT-IR spectrophotometer (Nicolet 560, Nicolet Co., Madison, WI). All spectra were recorded in absorption mode in the wavelength range of 1000–2200 cm−1 with a resolution of 4.0 cm−1 and 16-times scanning.

The water contact angles of the matrices were measured by the sessile drop method using a contact angle measurement system (OCA10, Dataphysics, Filderstadt, Germany). A 10 μl sessile drop of distilled water was formed on all samples.

The XRD patterns were measured using the X-ray diffractometer (Empyrean series 2, PANalytical, Almelo, Netherlands) with Cu-Kα radiation (λ = 0.154 nm) at 40 kV and 30 mA. The measurements were taken at a scan rate of 2° min−1 over the 2θ range of 5–50° at RT.

To examine the mechanical properties of the matrices, the stress–strain curves of the matrices were obtained by a tabletop tensile tester (LRX Plus Series, Ametek Lloyd Instruments Ltd., Fareham, UK) equipped with a 5 kN load cell under a cross-head speed of 10 mm/min. Prior to testing, 4 types of matrices were cut into a rectangular shape, 40 mm in length and 10 mm in width.

Cell attachment and proliferation assays

C2C12 skeletal myoblasts were purchased from the American Type Culture Collection (Rockville, MD) and routinely maintained in GM, DMEM (Welgene, Daegu, Korea) supplemented with 10% foetal bovine serum (FBS, Welgene) and 1% antibiotic-antimycotic solution (including 10,000 units penicillin, 10 mg streptomycin and 25 μg amphotericin B per ml, Sigma-Aldrich Co.) at 37 °C in a humidified atmosphere containing 5% CO2.

The initial attachment and proliferation were measured by using a cell counting kit-8 (CCK-8, Dojindo, Kumamoto, Japan) according to the manufacturer’s instruction. The number of viable cells was directly proportional to the metabolic reaction products obtained in the CCK-8 assay [16]. Briefly, the C2C12 skeletal muscle cells were seeded at a density of 1 × 104 cells/mL on the PLGA, GO-PLGA, PLGA-Col, and GO-PLGA-Col matrices. The cells were incubated with a CCK-8 solution in the last 2 hours of the culture periods for the initial attachment (6 hours) or proliferation (1, 3, 5, and 7 days) at 37°C in the dark. Parallel sets of cells were cultured on the TCPs and the results were regarded as the positive (+) controls. The absorbance was measured at 450 nm using an ELISA reader (SpectraMax 340, Molecular Device Co., Sunnyvale, CA).

Myogenic differentiation analysis with immunofluorescence staining

C2C12 skeletal myoblasts were seeded at a density of 1 × 104 cells/mL on PLGA, GO-PLGA, PLGA-Col, or GO-PLGA-Col matrices. The cells were cultured in GM for 2 days. The cells were then cultured in GM or DM for an additional 5 days in order to investigate the myogenic differentiation of C2C12 skeletal myoblasts. The media were changed every 24 hours. After culturing under each condition, the cells were fixed with a 3.7% formaldehyde solution (Sigma-Aldrich Co.) for 10 minutes and immersed in 0.1% Triton X-100 (Sigma-Aldrich Co.) for 5 minutes. Subsequently, the cells were blocked with a 2% bovine serum albumin (BSA, GenDEPOT, Barker, TX) solution in Dulbecco’s phosphate-buffered saline (DPBS, Gibco BRL, Rockville, MD) for 30 minutes. The cells were incubated with an Alexa Fluor 488 conjugated anti-MHC monoclonal antibody (clone MF20, 1:200 in 1% BSA solution in DPBS; eBioscienceInc., San Diego, CA) overnight at 4°C, followed by incubation with TRITC-labelled phalloidin (200 units/ml in methanol, 1:40 in 1% BSA solution in DPBS; Molecular Probes, Eugene, OR) for 20 minutes in the dark at RT. The nuclei were counterstained with a DAPI (Sigma-Aldrich Co.) solution in DPBS. The stained cells were imaged using a custom-built two-photon excitation fluorescence microscope, as described elsewhere, and analysed using ImageJ software (National Institutes of Health, Bethesda, MD) [60,61].

Statistical analysis

All variables were tested in three independent cultures for each experiment, which was repeated twice (n = 6). The quantitative data is expressed as the mean ± standard deviation (SD). The data was tested for the homogeneity of the variances using the test of Levene, prior to statistical analysis. Statistical comparisons were carried out using a one-way analysis of variance (ANOVA; SAS Institute Inc., Cary, NC, USA), followed by a Bonferroni test for multiple comparisons. A value of p < 0.05 was considered statistically significant.

Abbreviations

AFM:

Atomic force microscopy

ANOVA:

Analysis of variance

BSA:

Bovine serum albumin

CCK-8:

Cell counting kit-8

Col:

Collagen

DAPI:

4’,6-diamidino-2-phenylindole

DC:

Direct current

DM:

Differentiation media

DMEM:

Dulbecco’s modified Eagle’s medium

DPBS:

Dulbecco’s phosphate-buffered saline

ECM:

Extracellular matrix

ELISA:

Enzyme-linked immunosorbent assay

FBS:

Foetal bovine serum

FESEM:

Field emission scanning electron microscopy

FITC:

fluorescein isothiocyanate

FT-IR:

Fourier transform-infrared

GM:

Growth media

GO:

Graphene oxide

GO-PLGA-Col:

Graphene oxide-impregnated poly(lactic-co-glycolic acid)-collagen

HFIP:

1, 1, 1, 3, 3, 3-hexafluoroisopropanol

MHC:

Myosin heavy chain

MW:

Molecular weight

PLGA:

Poly(lactic-co-glycolic acid)

RT:

Room temperature

SD:

Standard deviation

TCP:

Tissue culture plastic

TRITC:

tetramethylrhodamine isothiocyanate

XRD:

X-ray diffraction

References

  1. Murugan R, Ramakrishna S. Design strategies of tissue engineering scaffolds with controlled fibre orientation. Tissue Eng. 2007;13:1845–66.

    Article  CAS  Google Scholar 

  2. Zhang L, Webster TJ. Nanotechnology and nanomaterials: promises for improved tissue regeneration. Nano Today. 2009;4:66–80.

    Article  CAS  Google Scholar 

  3. Agarwal S, Wendorff JH, Greiner A. Use of electrospinning technique for biomedical applications. Polymer. 2008;49:5603–21.

    Article  CAS  Google Scholar 

  4. Pham QP, Sharma U, Mikos AG. Electrospinning of polymeric nanofibers for tissue engineering applications: A review. Tissue Eng. 2006;12:1197–211.

    Article  CAS  Google Scholar 

  5. Armentano I, Dottori M, Fortunati E, Mattioli S, Kenny JM. Biodegradable polymer matrix nanocomposites for tissue engineering: a review. Polym Degrad Stabil. 2010;95:2126–46.

    Article  CAS  Google Scholar 

  6. Hasan A, Memic A, Annabi N, Hossain M, Paul A, Dokmeci MR, et al. Electrospun scaffolds for tissue engineering of vascular grafts. Acta Biomater. 2014;10:11–25.

    Article  CAS  Google Scholar 

  7. Jung D, Minami I, Patel S, Lee J, Jiang B, Yuan Q, et al. Incorporation of functionalized gold nanoparticles into nanofibers for enhanced attachment and differentiation of mammalian cells. J Nanobiotechnol. 2012;10:119–26.

    Article  Google Scholar 

  8. Kumar A, Patel A, Duvalsaint L, Desai M, Marks ED. Thymosin β4 coated nanofiber scaffolds for the repair of damaged cardiac tissue. J Nanobiotechnol. 2014;12:10.

    Article  Google Scholar 

  9. Riboldi SA, Sampaolesi M, Neuenschwander P, Cossu G, Mantero S. Electrospun degradable polyesterurethane membranes: potential scaffolds for skeletal muscle tissue engineering. Biomaterials. 2005;26:4606–15.

    Article  CAS  Google Scholar 

  10. Choi JS, Lee SJ, Christ GJ, Atala A, Yoo JJ. The influence of electrospun aligned poly(ε-caprolactone)/collagen nanofiber meshes on the formation of self-aligned skeletal muscle myotubes. Biomaterials. 2008;29:2899–906.

    Article  CAS  Google Scholar 

  11. Ricotti L, Polini L, Genchi GG, Ciofani G, Iandolo D, Vazão H, et al. Proliferation and skeletal myotube formation capability of C2C12 and H9c2 cells on isotropic and anisotropic electrospun nanofibrous PHB scaffolds. Biomed Mater. 2012;7:035010.

    Article  Google Scholar 

  12. Guex AG, Birrer DL, Fortunato G, Tevaearai HT, Giraud MN. Anisotropically oriented electrospun matrices with an imprinted periodic micropattern: a new scaffold for engineered muscle constructs. Biomed Mater. 2013;8:021001.

    Article  Google Scholar 

  13. Beier JP, Klumpp D, Rudisile M, Dersch R, Wendorff JH, Bleiziffer O, et al. Collagen matrices from sponge to nano: new perspectives for tissue engineering of skeletal muscle. BMC Biotechnol. 2009;9:34.

    Article  Google Scholar 

  14. Ciofani G, Ricotti L, Menciassi A, Mattoli V. Preparation, characterization and in vitro testing of poly(lactic-co-glycolic) acid/barium titanate nanoparticle composites for enhanced cellular proliferation. Biomed Microdevices. 2011;13:255–66.

    Article  CAS  Google Scholar 

  15. Chen DW, Hsu YH, Liao JY, Liu SJ, Chen JK, Ueng SWN. Sustainable release of vancomycin, gentamicin and lidocaine from novel electrospun sandwich-structured PLGA/collagen nanofibrous membranes. Int J Pharmaceut. 2012;430:335–41.

    Article  CAS  Google Scholar 

  16. Lee EJ, Lee JH, Jin L, Jin OS, Shin YC, Oh SJ, et al. Hyaluronic acid/poly(lactic-co-glycolic acid) core/shell fibre meshes loaded with epigallocatechin-3-O-gallate as skin tissue engineering scaffolds. J Nanosci Nanotechnol. 2014;14:8458–63.

    Article  CAS  Google Scholar 

  17. Pirooznia N, Hasannia S, Lotfi AS, Ghanei M. Encapsulation of Alpha-1 antitrypsin in PLGA nanoparticles: In Vitro characterization as an effective aerosol formulation in pulmonary diseases. J Nanobiotechnol. 2012;10:20.

    Article  CAS  Google Scholar 

  18. Shin YC, Yang WJ, Lee JH, Oh JW, Kim TW, Park JC, et al. PLGA nanofiber membranes loaded with epigallocatechin-3-O-gallate are beneficial to prevention of postsurgical adhesions. Int J Nanomed. 2014;9:4067–78.

    CAS  Google Scholar 

  19. Lee JH, Shin YC, Yang WJ, Park JC, Hyon SH, Han DW. Epigallocatechin-3-O-gallate-loaded poly(lactic-co-glycolic acid) fibrous sheets as anti-adhesion barriers. J Biomed Nanotechnol 2015;11. doi:10.1166/jbn.2015.2080.

  20. Wang Y, Li Z, Wang J, Li J, Lin Y. Graphene and graphene oxide: biofunctionalization and applications in biotechnology. Trends Biotechnol. 2011;29:205–12.

    Article  Google Scholar 

  21. Veerapandian M, Seo YT, Shin H, Yun K, Lee MH. Fabrication and characterization of aligned nanofibrous PLGA/collagen blends as bone tissue scaffolds. Int J Nanomed. 2012;7:6123–36.

    Article  CAS  Google Scholar 

  22. Wang H, Gu W, Xiao N, Ye L, Xu Q. Chlorotoxin-conjugated graphene oxide for targeted delivery of an anticancer drug. Int J Nanomed. 2014;9:1433–42.

    Google Scholar 

  23. Varela JN, Amstalden MCK, Pereira RFC, Hollanda LM, Ceragioli HJ, Baranauskas V, et al. Haemophilus influenzae porine ompP2 gene transfer mediated by graphene oxide nanoparticles with effects on transformation process and virulence bacterial capacity. J Nanobiotechnol. 2014;12:14.

    Article  Google Scholar 

  24. Ruiz ON, Fernando KAS, Wang B, Brown NA, Luo PG, McNamara ND, et al. Graphene oxide: a nonspecific enhancer of cellular growth. ACS Nano. 2011;5:8100–7.

    Article  CAS  Google Scholar 

  25. Yoon OJ, Jung CY, Sohn IY, Kim HJ, Hong B, Jhon MS, et al. Nanocomposite nanofibers of poly(D, L-lactic-co-glycolic acid) and graphene oxide nanosheets. Compos Part A-Appl S. 2011;42:1978–84.

    Article  Google Scholar 

  26. Yoon OJ, Sohn IY, Kim DJ, Lee NE. Enhancement of thermomechanical properties of poly(D, L-lactic-co-glycolic acid) and graphene oxide composite films for scaffolds. Macromol Res. 2012;20:789–94.

    Article  CAS  Google Scholar 

  27. Wu S, Zhao X, Cui Z, Zhao C, Wang Y, Du L, et al. Cytotoxicity of graphene oxide and graphene oxide loaded with doxorubicin on human multiple myeloma cells. Int J Nanomed. 2014;9:1413–21.

    Google Scholar 

  28. Jose MV, Thomas V, Dean DR, Nyairo E. Fabrication and characterization of aligned nanofibrous PLGA/collagen blends as bone tissue scaffolds. Polymer. 2009;50:3778–85.

    Article  CAS  Google Scholar 

  29. Liu SJ, Kau YC, Chou CY, Chen JK, Wu RC, Yeh WL. Electrospun PLGA/collagen nanofibrous membrane as early-stage wound dressing. J Membrane Sci. 2010;335:23–9.

    Google Scholar 

  30. Deitzel JM, Kleinmeyer J, Harris D, Beck Tan NC. The effect of processing variables on the morphology of electrospun nanofibers and textiles. Polymer. 2001;42:261–72.

    Article  CAS  Google Scholar 

  31. Xu C, Yang F, Wang S, Ramakrishna S. In vitro study of human vascular endothelial cell function on materials with various surface roughness. J Biomed Mater Res A. 2004;71:154–61.

    Article  Google Scholar 

  32. Milleret V, Hefti T, Hall H, Vogel V, Eberli D. Influence of the fibre diameter and surface roughness of electrospun vascular grafts on blood activation. Acta Biomater. 2012;8:4349–56.

    Article  CAS  Google Scholar 

  33. Sabba D, Mathews N, Chua J, Pramana SS, Mulmudi HK, Wang Q, et al. High-surface-area, interconnected, nanofibrillar TiO2 structures as photoanodes in dye-sensitized solar cells. Scripta Mater. 2013;68:487–90.

    Article  CAS  Google Scholar 

  34. Khalil KA, Fouad H, Elsarnagawy T, Almajhdi FN. Preparation and characterization of electrospun PLGA/silver composite nanofibers for biomedical applications. Int J Electrochem Sc. 2013;8:3483–93.

    Google Scholar 

  35. Sionkowska A, Wisniewski M, Skopinska J, Kennedy CJ, Wess TJ. Molecular interactions in collagen and chitosan blends. Biomaterials. 2004;25:795–801.

    Article  CAS  Google Scholar 

  36. Marcano DC, Kosynkin DV, Berlin JM, Sinitskii A, Sun Z, Slesarev A, et al. Improved synthesis of graphene oxide. ACS Nano. 2010;4:4806–14.

    Article  CAS  Google Scholar 

  37. Zuo PP, Feng HF, Xu ZZ, Zhang LF, Zhang YL, Xia W, et al. Fabrication of biocompatible and mechanically reinforced graphene oxide-chitosan nanocomposite films. Chem Cent J. 2013;7:39.

    Article  Google Scholar 

  38. Wu N, She X, Yang D, Wu X, Su F, Chen Y. Synthesis of network reduced graphene oxide in polystyrene matrix by a two-step reduction method for superior conductivity of the composite. J Mater Chem. 2012;22:17254–61.

    Article  CAS  Google Scholar 

  39. Zhao G, Schwartz Z, Wieland M, Rupp F, Geis-Gerstorfer J, Cochran DL, et al. High surface energy enhances cell response to titanium substrate microstructure. J Biomed Mater Res A. 2005;74:59–8.

    Google Scholar 

  40. Kim CH, Khil MS, Kim HY, Lee HU, Jahng KY. An improved hydrophilicity via electrospinning for enhanced cell attachment and proliferation. J Biomed Mater Res B. 2006;78:283–90.

    Article  Google Scholar 

  41. Donovan DL, Schmidt SP, Townshend SP, Njus GO, Sharp WV. Material and structural characterization of human saphenous vein. J Vasc Surg. 1990;12:531–7.

    Article  CAS  Google Scholar 

  42. Ma K, Chan CK, Liao S, Hwang WYK, Feng Q, Ramakrishna S. Electrospun nanofiber scaffolds for rapid and rich capture of bone marrow-derived hematopoietic stem cells. Biomaterials. 2008;29:2096–103.

    Article  CAS  Google Scholar 

  43. Zhang N, Qiu H, Si Y, Wang W, Gao J. Fabrication of highly porous biodegradable monoliths strengthened by graphene oxide and their adsorption of metal ions. Carbon. 2011;49:827–37.

    Article  CAS  Google Scholar 

  44. Grinou A, Yun YS, Jin HJ. Polyaniline nanofiber-coated polystyrene/graphene oxide core-shell microsphere composites. Macromol Res. 2012;20:84–92.

    Article  CAS  Google Scholar 

  45. Lee WC, Lim CHYX, Shi H, Tang LAL, Wang Y, Lim CT, et al. Origin of enhanced stem cell growth and differentiation on graphene and graphene oxide. ACS Nano. 2011;5:7334–41.

    Article  CAS  Google Scholar 

  46. Kato K, Gurdon JB. Single-cell transplantation determines the time when Xenopus muscle precursor cells acquire a capacity for autonomous differentiation. Proc Natl Acad Sci U S A. 1993;90:1310–4.

    Article  CAS  Google Scholar 

  47. Gurdon JB, Lemaire P, Kato K. Community effects and related phenomena in development. Cell. 1993;75:831–4.

    Article  CAS  Google Scholar 

  48. Skerjanc IS, Slack RS, McBurney MW. Cellular aggregation enhances MyoD-directed skeletal myogenesis in embryonal carcinoma cells. Mol Cell Biol. 1994;14:8451–9.

    CAS  Google Scholar 

  49. Cossu G, Kelly R, Donna SD, Vivarelli E, Buckingham M. Myoblast differentiation during mammalian somitogenesis is dependent upon a community effect. Proc Natl Acad Sci U S A. 1995;92:2254–8.

    Article  CAS  Google Scholar 

  50. Redfield A, Nieman MT, Knudsen KA. Cadherins promote skeletal muscle differentiation in three-dimensional cultures. J Cell Biol. 1997;138:1323–31.

    Article  CAS  Google Scholar 

  51. Hou J, Zhang H, Yuan X, Li J, Wei Y, Hu S. In vitro effects of low-level laser irradiation for bone marrow mesenchymal stem cells: Proliferation, growth factors secretion and myogenic differentiation. Laser Surg Med. 2008;40:726–33.

    Article  Google Scholar 

  52. Buckingham M. How the community effect orchestrates muscle differentiation. Bioessays. 2012;25:13–6.

    Article  Google Scholar 

  53. Ku SH, Park CB. Myoblast differentiation on graphene oxide. Biomaterials. 2013;34:2017–23.

    Article  CAS  Google Scholar 

  54. Nayak TR, Andersen H, Makam VS, Khaw C, Bae S, Xu X, et al. Graphene for controlled and accelerated osteogenic differentiation of human mesenchymal stem cells. ACS Nano. 2011;5:4670–8.

    Article  CAS  Google Scholar 

  55. Park SY, Park J, Sim SH, Sung MG, Kim KS, Hong BH, et al. Enhanced differentiation of human neural stem cells into neurons on graphene. Adv Healthc Mater. 2011;23:H263–7.

    Article  CAS  Google Scholar 

  56. Lee TJ, Park S, Bhang SH, Yoon JK, Jo I, Jeong GJ, et al. Graphene enhances the cardiomyogenic differentiation of human embryonic stem cells. Biochem Biophys Res Commun. 2014;452:174–80.

    Article  CAS  Google Scholar 

  57. Chen GY, Pang DWP, Hwang SM, Tuan HY, Hu YC. A graphene-based platform for induced pluripotent stem cells culture and differentiation. Biomaterials. 2012;33:418–27.

    Article  Google Scholar 

  58. Standley HJ, Zorn AM, Gurdon JB. eFGF and its mode of action in the community effect during Xenopus myogenesis. Development. 2001;128:1347–57.

    CAS  Google Scholar 

  59. Hummers WS, Offeman RE. Preparation of graphitic oxide. J Am Chem Soc. 1958;80:1339.

    Article  CAS  Google Scholar 

  60. Majewska A, Yiu G, Yuste R. A custom-made two-photon microscope and deconvolution system. Pflüg Arch Eur J Phy. 2000;441:398–408.

    Article  CAS  Google Scholar 

  61. Hovhannisyan V, Hu PS, Chen SJ, Kim CS, Dong CY. Elucidation of the mechanisms of optical clearing in collagen tissue with multiphoton imaging. J Biomed Opt. 2013;18:046004.

    Article  Google Scholar 

Download references

Acknowledgements

This research was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute, funded by the Ministry of Health & Welfare, Republic of Korea (No. HI14C0522).

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Suck Won Hong or Dong-Wook Han.

Additional information

Competing interests

The authors report no conflicts of interest in this work.

Authors’ contributions

YCS and JHL designed the experiments, fabricated the electrospun matrices by electrospinning, participated in the acquisition and analysis of the two-photon excitation fluorescence images, and drafted the manuscript. LJ and MJK contributed in the physicochemical characterisation of the matrices and participated in the cell cultures and in vitro assays. TGJ carried out the mechanical characterisation of the matrices. YJK and JKH performed the statistical analysis and helped interpret the data. SWH and DWH conceived of the study, participated in its design and coordination, and helped to draft the manuscript. All authors read and approved the final manuscript.

Yong Cheol Shin and Jong Ho Lee contributed equally to this work.

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shin, Y.C., Lee, J.H., Jin, L. et al. Stimulated myoblast differentiation on graphene oxide-impregnated PLGA-collagen hybrid fibre matrices. J Nanobiotechnol 13, 21 (2015). https://doi.org/10.1186/s12951-015-0081-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12951-015-0081-9